Perkins Series 160kW / 200kVA Diesel Generator Set
The standard configuration is suitable for factory backup power, construction site power, commercial facilities, telecom infrastructure, public facilities and emergency standby power supply. Open type, silent type and super silent type configurations are available according to noise control, installation space and project requirements.
- Prime power: 160kW / 200kVA; standby power: 176kW / 220kVA.
- Powered by Perkins 1206D-E70TTAG1 engine, 6-cylinder in-line, turbocharged and water-cooled.
- 50Hz, 1500r/min, 380/400/415V, 3-phase output.
- Available in open type, silent type and super silent type configurations.
- Standard SWT single-unit control system with LCD display, multilingual interface, protection functions and local/remote start.
- Optional ATS panel and SWT synchronizing system for automatic transfer and multi-unit operation.
- Each unit is factory tested at 0%, 25%, 50%, 75%, 100% and 110% load before delivery.
Technical Specifications
| Item | Specification |
| Genset Model | SP220 |
| Prime Power | 160kW / 200kVA |
| Standby Power | 176kW / 220kVA |
| Frequency | 50Hz |
| Rated Speed | 1500r/min |
| Rated Voltage | 380/400/415V |
| Power Factor | 0.8 |
| Open Type Size / Weight | 3035 × 900 × 1525 mm / 2135 kg |
| Silent Type Size / Weight | 3800 × 1130 × 2150 mm / 3195 kg |
| Super Silent Type Size / Weight | 3900 × 1340 × 2220 mm / 3696 kg |
| Operating Temperature | ≤40°C |
| Altitude | ≤1000 m |
| Relative Humidity | ≤60% |
Engine Specifications
| Item | Specification |
| Engine Brand | Perkins |
| Engine Model | 1206D-E70TTAG1 |
| Aspiration | Turbocharged |
| Cooling Method | Water-cooling |
| Cylinder Arrangement | 6 cylinders / in-line |
| Displacement | 7.01 L |
| Bore × Stroke | 105 mm × 127 mm |
| Compression Ratio | 15.8:1 |
| Rated Speed | 1500r/min |
| Prime / Standby Engine Power | 185.8kW / 204.2kW |
| Dry Weight | 797 kg |
| Governor | Electronic |
| Injection Type | Common Rail |
| Fuel Injection Pump | Denso HP4 |
| Fuel Injector | Denso G3S |
| Max Allowable Exhaust Back Pressure | 35 kPa |
| Maximum Intake Air Restriction | Clean filter: 3 kPa; Dirty filter: 5 kPa |
| Coolant Capacity | 25 L |
| Thermostat Operating Range | 82-93°C |
| Maximum Top Tank Temperature | 108°C |
| Lubrication Oil Capacity | 16 L |
| Max Continuous Oil Temperature | 125°C |
| Electrical System | Alternator: 100A-12V; Starter motor: 5kW-12V |
Fuel Consumption
| Load Condition | Fuel Consumption |
| 110% Prime Power | 51.0 L/h |
| 100% Prime Power | 45.8 L/h |
| 75% Prime Power | 34.7 L/h |
Alternator Specifications
| Item | Specification |
| Rated Voltage | 380/400/415V |
| Rated Frequency | 50Hz |
| Power Factor | 0.8 |
| Rated Power | 160kW / 200kVA |
| Insulation Class | H |
| Temperature Rise Class | H |
| Protection | IP23 |
| Ambient Temperature | 40°C |
| Altitude | ≤1000 m |
| Phases | 3 |
| Winding Pitch | 2/3 |
| No. of Bearing | 1 |
| Connection Type | Star |
| Poles | 4 |
| Waveform Distortion (THD) | <5% |
| Telephone Interference Factor (THF) | <2% |
SWT Single-Unit Control System
The standard SWT control system provides reliable monitoring, operation and protection for single-unit applications. The controller supports LCD display, key operation, multilingual interface, engine and alternator parameter detection, event logs and local or remote start.
- LCD screen and key operation
- Multilingual display
- Control and protection functions
- Engine and alternator parameter detection
- Local and remote start
- Multiple communication interfaces available
- Event logs and real-time clock for accurate operation records
- Parameters configurable through panel buttons or PC software via USB interface
- Voltage and current measurement
- Generator / mains circuit breaker control
- Upgradeable firmware and modular design for improved stability
ATS System Optional
An ATS panel can be provided for automatic transfer between mains power and generator power. The ATS controller integrates measurement, display and control functions and can be used for mains-to-mains or mains-to-generator applications.
- Microcomputer control with full digital technology
- LCD display for ATS operating status and controller mode
- Voltage and frequency measurement through LCD screen
- Fast on-load switching between two power sources with switching time ≤80ms
- Electrical and mechanical double interlock to prevent short circuit between two power sources
- Suitable for automatic backup power applications
SWT Paralleling System Optional
For projects requiring larger capacity or redundancy, SWT can provide a paralleling system for genset-to-genset or genset-to-grid applications. The system supports automatic synchronization of up to 32 units and can automatically start, parallel, load share, unload and cool down units according to load demand and mains power status.
- Supports genset-to-genset, genset-to-grid and paralleling with ATS applications
- Automatic start and synchronization of multiple units
- Load-based unit input and withdrawal to avoid high-power units operating at low load
- PLC system and touch screen available upon customer request
- Flexible expansion for future capacity increase
- Chinese and English operating system with built-in fault detection
Applications
The SWT 160kW / 200kVA Perkins diesel generator set is suitable for both prime and standby power applications where stable, reliable and easy-to-maintain power supply is required.
- Industrial plants and manufacturing facilities
- Commercial buildings and office complexes
- Construction sites and temporary power projects
- Telecom stations and infrastructure facilities
- Hospitals and public facilities
- Schools, hotels and commercial service buildings
- Remote operation areas and small industrial projects
- Emergency standby power supply
- Backup power for pumps, workshops and auxiliary equipment
Why Choose SWT 160kW / 200kVA Perkins Diesel Generator Set?
- Reliable Perkins engine: The generator set is powered by a Perkins 1206D-E70TTAG1 engine with common rail injection and electronic governor for stable operation.
- Flexible enclosure options: Open type, silent type and super silent type configurations are available to suit different installation and noise-control requirements.
- Factory-tested before delivery: Each generator set is tested under multiple load conditions before shipment to ensure stable performance and reliable protection functions.
- Smart control system: The standard control system supports engine and alternator monitoring, event logging, local and remote start and multiple optional communication interfaces.
- Project-ready configuration: ATS panel, synchronizing system, remote monitoring, cloud monitoring, trailer and fuel system options are available for customized power projects.
- Suitable for industrial backup power: The unit provides a practical power level for medium-size facilities, construction projects, commercial buildings and emergency standby applications.
Standard Accessories
- Engine
- Alternator
- Chassis
- Control box
- Controller for single unit
- Circuit breaker
- Industrial muffler
- Flange of muffler
- Bellow joint
- Shock absorber
- Test report
- Certificate of quality
- Schematic diagram
- Installation manual
- Operation manual
Optional Accessories
- Daily fuel tank / bulk fuel tank
- Residential silencer
- Power cable
- Anti-condensation heater for alternator
- Battery charger
- Water jacket heater
- Oil heater
- Fuel level sensor
- Auto oil make-up device
- Auto fuel filling device
- Soundproof enclosure
- Containerized enclosure
- Trailer
- Exhaust pipe
- Hot air discharge duct
- RS485 extension module
- Ethernet communication
- Cloud monitor
- ATS panel
- Motorized circuit breaker
- Synchronizing system
- Spare parts
- Deepsea, ComAp and SmartGen controller options
FAQ
| Question | Answer |
| What is the prime power of this generator set? | The prime power is 160kW / 200kVA, suitable for continuous operation under variable load conditions. |
| What is the standby power? | The standby power is 176kW / 220kVA. Standby power is designed for emergency use, with no overload allowed. |
| What engine does this generator set use? | This generator set is powered by a Perkins 1206D-E70TTAG1 diesel engine. |
| What voltage and frequency are available? | The standard configuration is 50Hz with rated voltage of 380/400/415V. Other project requirements can be discussed during quotation. |
| Is a silent type available? | Yes. Open type, silent type and super silent type configurations are available. |
| Can this generator work with ATS? | Yes. An ATS panel can be provided for automatic switching between mains power and generator power. |
| Can multiple units operate in parallel? | Yes. SWT can provide a synchronizing system for genset-to-genset or genset-to-grid applications, supporting automatic synchronization of up to 32 units. |
| What tests are carried out before delivery? | Each unit is tested at 0%, 25%, 50%, 75%, 100% and 110% load, together with static and transient response tests and inspection of protection devices and control systems. |
| What applications is this generator suitable for? | It is suitable for industrial plants, commercial buildings, construction sites, telecom facilities, public facilities and emergency standby power supply. |