1600kW / 2000kVA Perkins Diesel Generator Set
As a generator set manufacturer and power system integrator, SWT focuses on complete genset matching, structural design, control integration, factory testing and project customization. The generator set can be supplied in open type or 40ft containerized configuration according to installation environment, noise control requirements and project deployment needs.
- 1600kW / 2000kVA prime power and 1760kW / 2200kVA standby power output.
- 50Hz configuration with 1500r/min rated speed and 380/400/415V voltage options.
- Open type and 40ft containerized type available for different project conditions.
- Integrated SWT control system with LCD display, local and remote start, protection functions and event logs.
- ATS and paralleling system available for automatic transfer and multi-unit operation.
- Each generator set is tested before delivery under multiple load conditions.
- Suitable for industrial plants, data centers, mining, oilfield, infrastructure and emergency standby power projects.
Technical Specifications
| Item | Specification |
| Genset Model | SP2200 |
| Prime Power | 1600kW / 2000kVA |
| Standby Power | 1760kW / 2200kVA |
| Frequency | 50Hz |
| Rated Speed | 1500r/min |
| Rated Voltage | 380/400/415V |
| Power Factor | 0.8 |
| Engine Matching | Perkins 4016TAG2A |
| Alternator Rated Power | 1664kW / 2080kVA |
| Alternator Protection | IP23 |
| Insulation Class | H |
| Standard Operating Temperature | ≤40°C |
| Standard Altitude | ≤1000m |
| Standard Humidity | ≤60% |
Dimensions and Weight
| Configuration | Size L x W x H (mm) | Weight (kg) |
| Open Type | 5220 x 2130 x 2600 | 13155 |
| Silent Type | 40ft Container | 19500 |
Power Rating Definition
| Rating Type | Description |
| Prime Power (PRP) | The unit can run continuously for 24 hours under variable load. 10% overload is allowed for 1 hour every 12 hours. |
| Standby Power (ESP) | Designed for emergency use at an average load rate of 80%, for no more than 500 hours per year. No overload is allowed. |
Factory Testing
Before delivery, each generator set passes load tests at 0%, 25%, 50%, 75%, 100% and 110%, together with static and transient response checks. Protection devices and control systems are inspected before factory release.
Control System
The standard SWT control system is designed for single-unit operation and supports convenient operation, monitoring and protection. The specific controller model is subject to final quotation and project configuration.
- LCD screen with key operation.
- Multilingual display.
- Control and protection functions.
- Engine and alternator parameter detection.
- Local and remote start.
- Multiple communication interfaces available.
- Event logs for operation review.
- IP65 overall protection for the controller.
ATS Optional
An ATS panel can be configured for mains-to-generator or mains-to-mains automatic transfer applications. It combines measurement, display and control functions to support reliable automatic switching.
- Microcomputer control with digital technology.
- LCD display for operating state and controller mode.
- Voltage and frequency measurement through LCD screen.
- PC-level switch and electromagnetic driven structure for fast on-load switching of two power sources.
- Electrical and mechanical double interlock mechanism to improve switching safety.
- Optional communication module available according to project requirements.
SWT Paralleling System Optional
For projects requiring multiple generator sets or grid paralleling, SWT can provide a paralleling system for genset-to-genset, genset-to-grid and paralleling with ATS applications. The system supports automatic synchronization of up to 32 units and can be customized for load management and project control logic.
- Supports automatic synchronization and parallel operation.
- Can automatically start or stop units according to load demand.
- Helps avoid large-capacity units operating under low load for extended periods.
- Flexible expansion for future capacity increase.
- PLC system and touch screen are available upon request.
- Suitable for power station, industrial plant and critical backup power projects.
Applications
- Data center backup power
- Industrial plant prime or standby power
- Mining and heavy-duty site power supply
- Oilfield and energy project power supply
- Infrastructure and utility projects
- Commercial complex and large building standby power
- Emergency standby power systems
- Multi-unit power station projects
Why Choose SWT
- Complete generator set integration: SWT focuses on genset matching, frame design, enclosure configuration, control system integration and factory testing.
- Flexible configuration: open type, containerized type, ATS, paralleling system, remote communication and other options can be selected according to project requirements.
- Project-oriented design: the solution can be adapted for industrial, mining, energy, infrastructure and standby power scenarios.
- Factory-tested before delivery: every unit is tested under multiple load conditions to support stable operation after installation.
- System-level support: SWT can provide single-unit supply or multi-unit power system solutions for larger power demands.
Standard Accessories
| Standard Accessories |
| Test report |
| Certificate of quality |
| Schematic diagram |
| Installation manual |
| Operation manual |
| Engine |
| Alternator |
| Chassis |
| Control box |
| Controller for single unit |
| Circuit breaker |
| Industrial muffler |
| Flange of muffler |
| Bellow joint |
| Shock absorber |
Optional Accessories
| Optional Accessories | Optional Accessories |
| Daily fuel tank / bulk fuel tank | Residential silencer |
| Power cable | Anti-condensation heater for alternator |
| Battery charger | Water jacket heater |
| Oil heater | Fuel level sensor |
| Auto oil make-up device | Auto fuel filling device |
| Soundproof enclosure | Containerized enclosure |
| Trailer | Exhaust pipe |
| Hot air discharge duct | RS485 extension module |
| Ethernet communication | Cloud monitor |
| ATS panel | Motorized circuit breaker |
| Synchronizing system | Spare parts |
| Deepsea controller options | ComAp / SmartGen controller options |
FAQ
What is the prime power of the SWT SP2200 diesel generator set?
The prime power is 1600kW / 2000kVA, suitable for continuous operation under variable load conditions.
What is the standby power of this generator set?
The standby power is 1760kW / 2200kVA. Standby power is intended for emergency applications, and overload is not allowed.
What frequency and voltage options are available?
This configuration is designed for 50Hz operation with 380/400/415V voltage options.
Is a containerized configuration available?
Yes. In addition to open type configuration, a 40ft containerized silent type can be supplied according to project requirements.
Can the generator set work with ATS?
Yes. ATS can be configured for automatic transfer between mains power and generator power.
Can multiple units operate in parallel?
Yes. SWT can provide a paralleling system for set-to-set or set-to-grid applications, supporting automatic synchronization of up to 32 units.
What applications is this generator suitable for?
It is suitable for data centers, industrial plants, mining, oilfield, infrastructure projects, commercial buildings and emergency standby power systems.
Does SWT test the generator set before delivery?
Yes. Each unit is tested under multiple load levels, including 0%, 25%, 50%, 75%, 100% and 110%, with protection and control system inspection before delivery.





