MTU Series 1800kW / 2250kVA Diesel Generator Set
The SWT SM2500 diesel generator set is a high-power generator solution designed for industrial power supply, critical standby power and large-scale project applications. With 1800kW / 2250kVA prime power and 2000kW / 2500kVA standby power, this generator set is suitable for facilities that require stable output, flexible system configuration and reliable operation under demanding project conditions. SWT provides the complete generator set integration, including engine and alternator matching, base frame, control system, cooling arrangement, exhaust system, sound attenuation or containerized enclosure, testing and project customization.
For projects requiring lower noise, outdoor installation or faster site deployment, the SM2500 can be supplied with a 40-foot containerized silent configuration. The system can also be combined with ATS panels, synchronizing systems, fuel systems, communication modules and remote monitoring according to project requirements.
| Item | Specification |
| Genset Model | SM2500 |
| Prime Power | 1800kW / 2250kVA |
| Standby Power | 2000kW / 2500kVA |
| Frequency | 50Hz |
| Rated Speed | 1500r/min |
| Rated Voltage | 380/400/415V |
| Power Factor | 0.8 |
| Start Mode | DC24V electrical start |
| Open Type Size | 6100 × 2200 × 2750 mm |
| Open Type Weight | 16000 kg |
| Silent Type | 40-foot containerized configuration |
| Silent Type Weight | 18000 kg |
| Standard Operating Conditions | Ambient temperature ≤40°C, altitude ≤1000m, relative humidity ≤60% |
Key Highlights
- 1800kW / 2250kVA prime power output for large industrial and commercial power demand.
- 2000kW / 2500kVA standby power for emergency backup applications.
- 50Hz configuration with 380/400/415V voltage options.
- Available as open type or 40-foot containerized silent type for different installation environments.
- Integrated SWT control system for monitoring, protection, event logs, local start and remote start.
- Optional ATS system for automatic transfer between mains power and generator power.
- Optional SWT paralleling system for multi-unit operation and capacity expansion.
- Factory-tested before delivery, including load test and inspection of protection and control systems.
Technical Specifications
| Item | Specification |
| Model | SM2500 |
| Prime Power (PRP) | 1800kW / 2250kVA |
| Standby Power (ESP) | 2000kW / 2500kVA |
| Frequency | 50Hz |
| Rated Speed | 1500r/min |
| Rated Voltage | 380/400/415V |
| Power Factor | 0.8 |
| Start Mode | DC24V electrical start |
| Open Type Dimensions | 6100 × 2200 × 2750 mm |
| Open Type Weight | 16000 kg |
| Silent Type Configuration | 40-foot container |
| Silent Type Weight | 18000 kg |
| Operating Temperature | ≤40°C |
| Altitude | ≤1000m |
| Relative Humidity | ≤60% |
Note: When the ambient temperature is higher than 40°C or the altitude is higher than 1000 meters, output power should be corrected according to the actual operating conditions.
Integrated Power Package
The SM2500 generator set is configured as a complete power package. It includes matched major components, base frame, cooling arrangement, exhaust connection, control cabinet and protection functions. The engine is matched with the generator set power rating and project requirements, while the product page keeps engine details concise because SWT supplies the complete generator set system.
| Item | Specification |
| Engine Brand / Model | MTU 16V4000G24F |
| Alternator Rated Output | 1800kW / 2250kVA |
| Insulation Class | H |
| Temperature Rise Class | H |
| Protection Class | IP23 |
| Phase | 3-phase |
| Connection Type | Star |
| Waveform Distortion (THD) | <5% |
| Telephone Interference Factor (THF) | <2% |
SWT Control System
The standard SWT control system is designed for single-unit operation, monitoring and protection. It supports easy operation through LCD display and panel keys, while providing key operating data and event records for maintenance and operation management.
- LCD screen and key operation.
- Multilingual display.
- Control and protection functions.
- Engine and alternator parameter monitoring.
- Local and remote start.
- Multiple communication interfaces available.
- Event logs for operation and fault records.
- IP65 overall protection for the control unit.
- Parameter configuration through PC software where applicable.
ATS System Optional
An ATS panel can be provided as an optional configuration for applications requiring automatic transfer between mains power and generator power. The ATS controller integrates measurement, display and control functions, and is suitable for mains-to-mains or mains-to-generator systems.
- Microcomputer control with digital technology.
- LCD display for ATS operating status and controller mode.
- Voltage and frequency measurement through the controller display.
- Fast on-load switching of two power sources, with switching time up to 80ms depending on configuration.
- Electrical and mechanical double interlock design to improve system safety.
SWT Paralleling System Optional
For power plant projects or larger capacity applications, SWT can provide a paralleling system for genset-to-genset or genset-to-grid operation. The system supports automatic start, synchronizing, load sharing and unit management according to load demand.
- Supports automatic synchronizing of up to 32 generator sets.
- Suitable for genset-to-genset, gensets-to-grid and paralleling with ATS applications.
- Automatic operation and built-in fault detection.
- The system can input or remove units according to load demand to avoid high-power units operating under low load.
- Convenient for future capacity expansion by adding additional generator sets.
Applications
The SM2500 1800kW / 2250kVA diesel generator set is suitable for high-power projects and critical facilities requiring stable power supply.
- Data center backup power
- Industrial power supply
- Factory and manufacturing standby power
- Mining power supply
- Oilfield and energy project power supply
- Commercial complex backup power
- Infrastructure and utility projects
- Emergency power supply
- Power plant auxiliary and standby power
- Remote area prime power projects
Why Choose SWT
- Complete generator set integration: SWT supplies the full power package rather than a single component.
- Flexible configuration: open type, containerized silent type, ATS, synchronizing system and communication options are available.
- Project-oriented design: the generator set can be adapted to site conditions, installation requirements and operation mode.
- Reliable control system: monitoring, protection, event logs and local/remote start functions support easier operation.
- Factory testing before delivery: each unit is tested under multiple load levels and inspected before shipment.
- Scalable system solution: optional paralleling system supports larger power capacity and future expansion.
Standard Accessories
- Test report
- Certificate of quality
- Schematic diagram
- Installation manual
- Operation manual
- Engine and alternator package
- Base frame / chassis
- Control box
- Controller for single unit
- Industrial muffler
- Muffler flange
- Bellow joint
- Shock absorber
Optional Accessories
- Daily fuel tank or bulk fuel tank
- Residential silencer
- Power cable
- Anti-condensation heater for alternator
- Battery charger
- Water jacket heater
- Oil heater
- Fuel level sensor
- Automatic oil make-up device
- Automatic fuel filling device
- Soundproof enclosure
- Containerized enclosure
- Trailer
- Exhaust pipe
- Hot air discharge duct
- RS485 extension module
- Ethernet communication
- Cloud monitor
- ATS panel
- Motorized circuit breaker
- Synchronizing system
- Spare parts
FAQ
What is the prime power of the SWT SM2500 diesel generator set?
The prime power is 1800kW / 2250kVA. It is suitable for continuous operation under variable load conditions according to PRP definition.
What is the standby power of this generator set?
The standby power is 2000kW / 2500kVA. Standby power is intended for emergency use and no overload is allowed.
Is a silent type available?
Yes. A 40-foot containerized silent configuration is available for projects requiring lower noise, outdoor installation or easier deployment.
What voltage and frequency does this model support?
The standard configuration is 50Hz with rated voltage options of 380V, 400V and 415V.
Can this generator set be used with an ATS panel?
Yes. ATS is available as an optional configuration for automatic transfer between mains power and generator power.
Can multiple SM2500 units operate in parallel?
Yes. SWT can provide a paralleling system for multiple generator sets. The system can support automatic synchronizing of up to 32 units.
What tests are carried out before delivery?
Each unit passes load testing at 0%, 25%, 50%, 75%, 100% and 110%, and the protection devices and control systems are inspected before delivery.
What applications is this generator set suitable for?
It is suitable for data centers, industrial plants, mining projects, oilfield projects, infrastructure projects, emergency backup power and remote prime power applications.